Sump Pump Size Calculator

A typical basement pump lifting water 10 ft, through 20 ft of 1-1/2 inch pipe with three elbows, works against about 14 ft of total head. Our calculator sizes that as a 1/3 HP pump moving about 2,400 gallons per hour.

Free · No sign-up · Last reviewed

Quick start:

Your project size

(ft)
ft
(ft)
ft
(fittings)
fittings

Recommended Pump Horsepower

1/3 HP Total Dynamic Head: 15 Feet

Discharge Flow Capacity

2,400 GPH at 15' Dynamic Head

Want a real price for this sump pump size calculator project?

Get up to 3 free quotes from local contractors. No obligation. Your numbers are included.

Materials list

MaterialQuantityUnitNotes
Submersible Cast Iron Sump Pump (1/3 HP Residential Sump Pump)1PumpContinuous oil-filled motor with dual thermal protection
Schedule 40 PVC Discharge Pipe (1.5")25FeetSolvent-welded rigid discharge line
Silent Spring-Loaded Check Valve1ValveEliminates water hammer noise upon pump shutoff
Deep Cycle Battery Backup System (Optional)1SystemProvides 48 hours of pumping during power outages

Estimated cost: DIY vs. contractor

National Average
DIY Raw Materials Only
$220 – $380

Cost of raw lumber, concrete, shingles, wire, or stone without equipment rentals or labor.

Hired contractor
$650 – $1,100

Full installation: permits, site prep, skilled trade labor, equipment, and structural warranty.

Estimated Sweat Equity
~$575

Average trade labor savings if executed as a skilled DIY homeowner project.

Total Dynamic Head (TDH) & Pump Curve Formula

Rendering formula...

TDH Hydraulics for 10' Vertical Lift × 25' Run with 3 Elbows

  1. Static Head (Vertical Height from Basin to Discharge Rim) = 10 feet.
  2. Friction Head Loss (25' pipe + 3 elbows at 3.5' equiv) = 2.8 feet.
  3. Component Resistance (Check Valve + Basin Discharge) = 2.0 feet.
  4. Total Dynamic Head (TDH) = 10 + 2.8 + 2.0 = 15 feet.
  5. Pump Selection: Sump pumps operating at 15' TDH require a 1/3 HP motor to maintain reliable flow.
Tip: In National Average, drill a 3/16" weep hole in the discharge pipe between the pump and the check valve to prevent air-locking.

Quick Reference Sizing & Coverage Table

Standard commercial specifications and pre-calculated project benchmarks.

Vertical LiftTotal Dynamic HeadInflow SeverityRecommended HP SizeReplacement Cost
8 ft Lift9.5 ft TDHLow / Moderate Inflow1/3 HP (2,200 GPH)$350 – $650
10 ft Lift12.0 ft TDHAverage Spring Rains1/2 HP (3,000 GPH)$450 – $800
14 ft Lift16.5 ft TDHHigh Water Table1/2 HP or 3/4 HP$600 – $1,100
18 ft Lift22.0 ft TDHExtreme Storm Conditions3/4 HP (Cast Iron) + Battery$950 – $1,800
International Plumbing Code Section 712

IPC Chapter 7 & Check Valve Requirements

Discharge piping must include an accessible spring-loaded check valve and union within 12 inches of the pump discharge. Sump pump water must never discharge into municipal sanitary sewers.

How to use the sump pump calculator

  1. Measure the vertical lift from the bottom of the sump pit to where the pipe leaves the house.
  2. Enter the total length of discharge pipe and count the elbows.
  3. Pick the pipe diameter. The result shows total dynamic head, horsepower and flow.

What size sump pump do I need?

Pumps are rated by how much water they move against a given head, so work out the head first.

BasementLiftPipe runElbowsPipeTotal headPump
Standard10 ft20 ft31-1/2"14 ft1/3 HP
High water table10 ft10 ft22"13 ft1/3 HP
Deep walkout14 ft40 ft41-1/2"20 ft1/2 HP

When you shop, check the pump's flow chart at your total head, not just the horsepower.

What is total dynamic head?

It's the vertical lift plus the friction in the pipe and fittings. Our calculator counts each elbow as 3.5 ft of extra pipe and adds 2 ft for the check valve and pit outlet. For the standard basement: 10 ft lift + 2.4 ft pipe friction + 2.0 ft fittings = 14 ft (rounded).

Frequently asked questions

Does a bigger discharge pipe help?

Yes. A 2-inch pipe has less friction than 1-1/2 inch. The high-water-table setup above loses only 0.6 ft to friction over its 10 ft run.

What does a sump pump cost to install?

Our calculator estimates $650 to $1,100 for a professional install, or $220 to $380 for the pump and parts alone.

Do I need a battery backup sump pump?

A battery backup keeps running during a power cut, which is often when storms flood basements. Our calculator lists it as an optional extra.

Sources and review