Solar Battery Bank Capacity (kWh) & Off-Grid Runtime Calculator

Calculate usable battery storage in kWh, days of autonomy, inverter depth of discharge (DoD), and runtime for critical household appliance circuits.

Free · No sign-up · Last reviewed

Quick start:

Your project size

(kWh/day)
kWh/day

Required Usable Storage Capacity

30 kWh Storage (3 Units of 13.5 kWh)

Days of Autonomy & Depth of Discharge

1.5 Days Backup at 90% Depth of Discharge

Want a real price for this solar battery bank capacity project?

Get up to 3 free quotes from local contractors. No obligation. Your numbers are included.

Materials list

MaterialQuantityUnitNotes
13.5 kWh Lithium Iron Phosphate (LFP) Battery Modules3Units10-year warranty with 100% daily cycle endurance
Integrated Hybrid Inverter & Energy Gateway1GatewayAutomated grid-disconnect sub-panel management
Critical Loads Subpanel (100A)1SubpanelPowers refrigeration, well pump, lighting, and medical devices

Estimated cost: DIY vs. contractor

National Average
DIY Raw Materials Only
$22,500 – $28,500

Cost of raw lumber, concrete, shingles, wire, or stone without equipment rentals or labor.

Hired contractor
$34,500 – $46,500

Full installation: permits, site prep, skilled trade labor, equipment, and structural warranty.

Estimated Sweat Equity
~$15,000

Average trade labor savings if executed as a skilled DIY homeowner project.

Battery Storage Capacity & Depth of Discharge (DoD) Formula

Rendering formula...

Storage Math for 18 kWh/Day Consumption over 1.5 Days

  1. Total Energy Demand = 18 kWh/day × 1.5 days = 27.0 kWh.
  2. Factoring 90% Depth of Discharge = 27.0 ÷ 0.9 = 30 kWh gross capacity.
  3. Standard Commercial Modules (13.5 kWh per battery): 30 ÷ 13.5 = 2.2 → 3 units.
Tip: In National Average, installing batteries inside temperature-controlled spaces (garage/basement) preserves cycle life during extreme seasonal heat and freeze.

Quick Reference Sizing & Coverage Table

Standard commercial specifications and pre-calculated project benchmarks.

Daily Backup ScopeRequired Usable kWhLFP Battery UnitsBackup Runtime (Zero Solar)Turnkey Installed Cost
Essential Loads (8 kWh/day)10 kWh UsableOne 10–13.5 kWh Pack24 – 30 Hours$10,500 – $14,000
Standard Home (18 kWh/day)20 – 25 kWh UsableTwo 13.5 kWh Packs28 – 36 Hours$18,000 – $24,000
Whole Home + AC (35 kWh/day)40 – 50 kWh UsableThree to Four Packs30 – 40 Hours$30,000 – $42,000
Off-Grid Estate (50 kWh/day)60 – 80 kWh Usable48+ Hours Autonomy5+ Rack Batteries$45,000 – $65,000
NFPA 855 Standard for the Installation of Stationary Energy Storage Systems

NFPA 855 Residential Energy Storage Systems (ESS)

Residential indoor battery installations are limited to a maximum of 20 kWh per unit and 80 kWh total capacity aggregate. Units must maintain 3 feet of separation from one another and must be installed on fire-rated drywall backing.

Frequently Asked Questions

How many batteries do I need to power a house for 24 hours?

An average home consuming 25 to 30 kWh per day without solar generation needs two standard 13.5 kWh batteries (such as two Tesla Powerwalls or Enphase 5Ps) to maintain essential lighting, refrigeration, and comfort for 24 hours.

Why is LFP chemistry preferred over NMC for home batteries?

Lithium Iron Phosphate (LFP) contains no cobalt or nickel, cannot experience thermal runaway fire propagation, supports 6,000+ charge cycles (compared to 3,000 for NMC), and allows 100% daily discharge without degradation.

Can a solar battery run a central air conditioner?

Yes, provided the battery system delivers high instantaneous peak surge power (or the AC has a soft-start module). A 3-ton AC draws 3,500 watts, consuming about 3.5 kWh for every hour of run time.

Are home solar batteries eligible for the 30% federal tax credit?

Yes. Under Section 25D of the US Inflation Reduction Act, standalone battery systems with a capacity of 3 kWh or greater qualify for an uncapped 30% federal income tax credit.