HVAC & Plumbing5 min read

SEER vs. SEER2: What Changed and What It Means for You

By SpanSizer Editorial Team
• Updated

Need Exact Math for Your Project?

Launch our free online tool: Heat Pump Size Calculator

Open Calculator

SEER vs. SEER2 — Assembly Anatomy

Interactive 3D Isometric Engineering Rig • Verified Model

Interactive Model
Interactive Spec Explorer:
sand = 1" (ICPI OK)
60mm Interlocking Pavers & Polymeric Joints1" ASTM C33 Washed Concrete Sand Bed (1")6" Compacted #57 Stone BaseASTM D4632 Geotextile Stabilization FabricEngineered interlocking paver assembly adhering to ICPI Tech Spec 2. Illustrates depth-ordered cross-section: compacted crushed aggregate sub-base, non-woven separation fabric, exactly 1 inch of uncompacted ASTM C33 washed concrete sand, interlocking concrete pavers, and spiked commercial edge restraint.

SEER2 replaced SEER on January 1, 2023. It measures the same thing, how much cooling a system delivers per unit of electricity over a season, but with an updated test that produces lower numbers. That's why a system rated 14.0 SEER under the old test can show 13.4 SEER2: the equipment didn't get worse, the yardstick changed. When you compare systems now, compare SEER2 to SEER2.

Executive Summary & Field Takeaway

TL;DR

- SEER2 is the successor to SEER, using an updated Department of Energy test.

- SEER2 numbers run lower than SEER numbers for the same equipment.

- Minimums since 2023: 13.4 SEER2 for central AC in the North; 14.3 SEER2 in the South and Southwest; 14.3 SEER2 and 7.5 HSPF2 for heat pumps nationwide.

- Higher is more efficient: at the same load, a 16 SEER2 system uses about 16% less cooling energy than a 13.4 SEER2 one (derived).

- Compare like with like: don't put an old SEER rating next to a new SEER2 rating.

What changed in 2023

The Department of Energy updated the test used to rate air conditioners and heat pumps, and new efficiency rules took effect on January 1, 2023, according to the ICC Building Safety Journal. The updated test produces lower SEER2 and EER2 ratings than the old SEER and EER for the same equipment. Carrier describes SEER2 as the successor to the pre-2023 SEER standard, shown on all air conditioners and heat pumps sold in the U.S. since that date.

Minimum efficiency by region

EquipmentRegionMinimum since 2023
Central air conditionerNorth13.4 SEER2
Central air conditionerSouth and Southwest14.3 SEER2
Central air conditionerSouthwest (added requirement)11.7 EER2
Heat pumpNationwide14.3 SEER2 and 7.5 HSPF2

Sources: Carrier for the SEER2 and HSPF2 minimums; the ICC article for the Southwest EER2 minimum. These apply to split systems for homes; check your installer's paperwork for the exact rating of the model you're buying.

Old SEER vs. new SEER2

The ICC article gives the regional changes side by side:

RegionBefore 2023Since 2023
North13.0 SEER14.0 SEER, which is 13.4 SEER2
Southeast14.0 SEER14.3 SEER2
Southwest14.0 SEER and 12.2 EER14.3 SEER2 and 11.7 EER2

There isn't a single conversion factor that works for every model, because each system responds a little differently to the new test. Use the SEER2 number on the label or in the manufacturer's listing.

How much does a higher SEER2 save?

Cooling energy goes down as SEER2 goes up: for the same amount of cooling, energy use is proportional to 1 ÷ SEER2. Compared with a 13.4 SEER2 system:

SEER2Cooling energy vs. 13.4 SEER2
14.3about 6% less
16about 16% less
18about 26% less

(Derived: 1 − 13.4 ÷ 14.3, 1 − 13.4 ÷ 16 and 1 − 13.4 ÷ 18.) Your actual savings depend on how much you run the AC, your electricity rate and how well the system is sized and installed. In a mild climate, a higher rating pays back more slowly than in a hot one.

What matters as much as the rating

  • Correct size. An oversized system short-cycles and wastes energy. Our guide to what size AC unit you need explains sizing, and the heat pump size calculator gives a starting estimate.
  • Installation quality. Refrigerant charge, airflow and leaky ducts all affect real-world efficiency.
  • HSPF2 for heat pumps. If you're buying a heat pump, its heating rating (HSPF2) matters as much as SEER2, especially in colder climates.

FAQ

Is 14.3 SEER2 good?

It's the minimum for new central air conditioners in the South and Southwest and for heat pumps nationwide. Higher-rated systems use less energy for the same cooling.

Can I still install an old SEER-rated unit?

Rules depend on the region and on when the unit was made. Ask your contractor what's allowed where you live before buying older stock.

Is SEER2 the same as EER2?

No. SEER2 is a seasonal average; EER2 measures efficiency at a single hot test condition. The Southwest has an EER2 minimum because peak-heat efficiency matters there.

Does a higher SEER2 mean a better system?

It means a more efficient one under test conditions. Correct sizing and good installation affect your comfort and bills as much as the rating does.

Sources

Free · No obligation

Rather hire it out? Compare local HVAC quotes

Tell us about your project and we'll share it with up to 3 contractors who serve your ZIP code. Always ask for proof of license and insurance before you hire.

Up to 3 local quotesFree for homeownersNo obligation to hire
How we build these guides

Quantities come from the same formulas as our calculators, and prices come from the sources listed in each guide. Read how SpanSizer works.