Blondel's Architectural Stair Rule & IRC R311.7 Code
IRC R311.7 Code Stair Derivation for 108" Total Rise
- Riser count: round(108" / 7.5") = 14, at least ceil(108" / 7.75") = 14 to stay within the IRC maximum → 14 risers.
- Exact Riser Height: 108" / 14 = 7.714" (IRC maximum is 7.75").
- Tread Count: 14 risers - 1 = 13 treads.
- Total Horizontal Run: 13 × 10.5" tread depth = 136.5" (11.38 ft).
- Stringer cut diagonal: sqrt(108² + 136.5²) = 174" (16-ft 2x12 stock required).